EasyManua.ls Logo

Parker V300 - Page 21

Parker V300
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Bulletin 76-00 B
21
Item Description Kit Description Kit
1
9(3)
10(12)
12
17
18
19
21
24
33
Controller, V300
oil, Solenoid Valve
Retaining Clip,Coil
Pressure Transducer
Flow Switch, Water Line
Pipe, Threaded
Solenoid Valve, Water Line
Nylon Connector, Elbow
Level Switch, HBSR
Temperature Probe
120V Controller
4 Point
8 Point
12 Point
16 Point
20 Point
240V Controller
4 Point
8 Point
12 Point
16 Point
20 Point
209898
209899
209900
209901
209902
209924
209925
209926
209927
209928
4(15) Gasket, Flange Gasket Pkg, Flange 202078
4(15)
5
Gasket, Flange
Disc Strainer
Strainer Assembly, Disc 200912
4(15)
6
Gasket, Flange
Solenoid Valve, SV2
Solenoid Valve Assembly, Liquid Line 209369
4(15)
7
Gasket, Flange
Check Valve, CK4A-2 (
1
2" NPT)
Check Valve Assembly CK413X00NSN
8 Orice, 0.040" (
1
8" NPT) Plug Pkg, Orice 0.040" 208667
9
10(12)
Coil, Solenoid Valve
Retaining Clip, Coil
Coil Pkg
110-120V ~ 50-60Hz
220-240V ~ 50-60Hz
209073
209074
10(12) Retaining Clip, Coil Retaining Clip Pkg 206516
11 Orice, 0.026" (
1
8" NPT) Plug Pkg, Orice 0.026" 208665
12 Pressure Transducer Pressure Transducer 251062
13 Pressure Gauge, Ammonia
Pressure Gauge
760mm - 10.5 bar
30" - 150psig
309403
309401
14 Angle, Unibody (
1
4" NPT) Angle Unibody Assembly 106630
16 Pressure Regulator Pressure Regulator, A2B RA 209290
17 Flow Switch, Water Flow Switch Assembly 209324
18
19
21
Pipe, Threaded
Solenoid Valve, Water Line
Nylon Connector, Elbow
Solenoid Valve Assembly, Water Line 208787
20(6)
21(4)
Nylon Tubing
Nylon Connector, Elbow
Nylon Tubing, Bubbler 208668
22 Water Bubbler Water Bubbler Assembly 208789
24 Level Switch, HBSR
Level Switch Assembly (Sensor Only)
Level Switch for V200 (Depth Reducer)
209323
210549
25
26
27(2)
28
Differential Check Valve
3/8" x 3/8"FPT Elbow, Connector
Tubing (SS), Liquid Return
3/8" x 3/8"FPT, Connector
Differential Check Valve Assembly (HT)
Differential Check Valve Assembly (LT)
206536
251503
29 Unibody, Globe (
1
4" NPT) Globe Unibody Assembly 106621
30 Orice, 0.032" (
1
8" NPT) Plug Pkg, Orice 0.032" 208666
4(15)
31
Gasket, Flange
13mm (
1
2") Ring Adaptor
Ring Adapter 200095
33 Liquid Drainer Liquid Drainer 309625
35
[1]
Temperature Probe Temperature Probe, Sensor 209075
38 Orice, 0.028" (
1
8” NPT) Plug Pkg, Orice 0.028" 209365
39 Solenoid Valve, S6P Solenoid Valve Assembly, Vent Line 208982
Table 3: V300 Rapid Purger Repair Kits
1
Should the RTD require replacement, the factory setting must be changed in order to calibrate the RTD. Close the hand valve for the foul gas inlet and liquid feed
inlet. Remove the faulty RTD and connect the replacement RTD to the proper wiring. Place the RTD in a container with ice and water. Observe the temperature
reading on the controller screen and wait for it to stabilize. Once the temperature has stabilized change the offset to cause the temperature reading to be 0°C
(32°F). Double check the reading in the ice water bath and ensure that the RTD is reading 0°C (32°F). The RTD is now calibrated.