EasyManua.ls Logo

Parker Zander K-MT 10 - Page 47

Parker Zander K-MT 10
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN | User Manual Annex with technical documentation
K-MT 10-95/D3 45
Technical data
Operating Range
Site Selection frost-free indoor installation in a
non-hazardous environment
Ambient temperature 1,5 to 50 °C (24,7 to 122 °F)
Compressed air inlet temperature 25 to 50 °C (68 to 122 °F)
Max. operating pressure 16 bar
e
Min. operating pressure 5 bare
Medium Compressed air and gaseous nitrogen
Fluid group 2
Electrical connection
Mains voltage, standard 230 V, 50-60 Hz
Alternative voltage 115 V, 50-60 Hz and 24 V DC
Protection class IP65
Please note type plate and attached electrical circuit diagram!
Performance details
Type Volumetric
ow¹ in
m3/h
Nominal
2
pipe size
Upstream fi lter Downstream
lter
Nominal
Pressure
in bar
e
Nominal
temperat.
°C
K-MT 10 105 1 AAP025EGFI AOP025EGMI 16 50
K-MT 15 145 1 AAP025EGFI AOP025EGMI 16 50
K-MT 20 200 1 AAP025EGFI AOP025EGMI 16 50
K-MT 25 255 1.1/2 AAP030GGFI AOP030GGMI 16 50
K-MT 35 350 1.1/2 AAP030GGFI AOP030GGMI 16 50
K-MT 45 420 1.1/2 AAP035GGFX AOP035GGMX 16 50
K-MT 60 620 2 AAP040HGFX AOP040HGMX 16 50
K-MT 75 750 2 AAP040HGFX AOP040HGMX 16 50
K-MT 95 940 2.1/2 AAP045IGFX AOP045IGMX 16 50
1
. m/h, relating to 1 bara and 20°C at the compressor suction capacity. Subsequently com-
pressed to 7 bare and 35°C inlet ..temperature to the dryer at 100% relative humidity – for
pressure dewpoints of -25°C and -40°C.
2
In accordance with DIN ISO 228 (BSP-P); alternatively ANSI B 1.20.1 (NPT-F).
Noise emission
Noise level : +3 dB (A)
1
65 – 95 dB(A)
1
.. relative to free  eld measurement, 1 m surr.  eld
Dimensions
Věnujte pozornost rozměrovým výkresům a tabulce s rozměry a hmotnostmi na straně 52.