K-MT 10-95/D3 47
Additional spare parts
Order no. Maintenance
interval
Quantity Scope of delivery
ZHM100/450 12 months 1 Dewpoint sensor
LS5/ZR 12 months 1 Element ne lter muf er
RK-MANO.063SR0219-1 12 months 1 Vessel pressure gauge
Desiccant packs (complete dryer)
Typ Order-ID. Content
K-MT 10 K-MT10DESMIX
Both chambers have to be lled
completely with adequate desic-
cant packets acc. to the
maintenance instructions
K-MT 15 K-MT15DESMIX
K-MT 20 K-MT20DESMIX
K-MT 25 K-MT25DESMIX
K-MT 35 K-MT35DESMIX
K-MT 45 K-MT60DESMIX
K-MT 60 K-MT60DESMIX
K-MT 75 K-MT75DESMIX
K-MT 95 K-MT95DESMIX
Replacement Element fi lter : P - TYPE - GRADE
Sample: Filter AAP025EGFI (Element P025AA)
Filter AOP030GGMI (Element P030AO)