GB/IE
- 18 -
10. Charger indicator
Indicator status
Explanations and actions
Red LED Green LED
Off Flashing Ready for use
The charger is connected to the mains and is ready for use; there is no
battery pack in the charger.
On Off Charging
The charger is charging the battery pack in quick charge mode.
Off On The battery pack is fully charged (charging completed).
Action:
Take the battery pack out of the charger. Disconnect the charger from
the mains supply.
Flashing Off Adapted charging
The charger is in gentle charging mode. For safety reasons the charging
is performed less quickly and takes more than 1 hour. The reasons can
be:
- The battery pack has not been used for a very long time or an alrea-
dy fl at battery was further discharged (exhaustive discharge).
- The battery pack temperature is outside the ideal range (between
10° C and 45° C).
Action:
Wait for the charging to be completed; you can still continue to charge
the battery pack.
Flashing Flashing Fault
Charging is no longer possible. The battery pack is defective.
Action:
Never charge a defective battery pack. Take the battery pack out of
the charger.
On On Temperature fault
The battery pack is too hot (e.g. due to direct sunshine) or too cold
(below 0° C).
Action:
Remove the battery pack and keep it at room temperature
(approx. 20° C) for one day.
Anl_4513632.indb 18Anl_4513632.indb 18 17.01.13 10:0217.01.13 10:02