EN - 12
Operang
Speed Control
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Humidity Control
Eos is factory set to start at a humidity level of 88%. The start point can be adjusted in nine (9) levels
between 40% and 88%.
The humidity level is indicated by three LEDs, with each LED represenng every third level.
(3rd, 6th, and 9th levels, with each step changing the sensivity by 6%.)
When the set humidity level is reached, Eos switches to operang in forced exhaust mode only. When
the humidity level later drops below the set level, the unit connues to operate in forced mode for 20
minutes to stabilize the humidity level. Aer that, Eos returns to its normal heat exchange operaon..
Note: If the start point for forced exhaust mode is adjusted to a value lower than 88%, it can cause Eos to
operate solely in forced exhaust mode during the summer when relave humidity is high. To avoid this,
the start point should be adjusted to a higher level.
Control panel on the unit
Press to change the air ow.
Three selectable modes: 20, 40 or 60m³/h
Control panel on the unit
Press
to change humidity sensivity.
Nine levels: 40 – 88 %
Sengs
Remote Control
Select: Low Mid High
Low Mid High