AN1002
Switch2
Connections
Power connection - the Switch2 control unit requires a 12V DC power supply connected to the "12V" and
"0V" terminals. A simple 12V power supply with battery backup is recommended. The chosen supply must
be capable of providing enough current to cope with the reader, the alarm sounder (if tted) and whatever
lock is connected to the system.
Reader connection - Any of the Paxton range of readers and keypads can be connected to a Switch2. All
readers are colour coded in the same way to correspond to the labelled inputs on the control unit.
EXIT
Reader or Keypad
Door relay
Power
Alarm
12V
Red LED
Amber LED
Bell
12V
0V
N.C.
N.O.
COM
Green LED
Data
Caution: For 12V d.c readers only. For correct
connection of old 5V readers, please refer
to instructions.
Clock
Exit
Inputs
Contact
Media Detect
0V
PLACE SERIAL
NUMBER
LABEL HERE
Switch2
http://paxton.info/107
123456
EXIT
12V
12V DC
0V
Data
Clock
12V
LED
LED
LED
Paxton
Switch2
Model No: 405-321
Made in the UK
http://paxton.info/107
12 V DC
80mA
Paxton
4488709
Reader
12V DC Alarm
Fail open or fail closed lock
12V DC power supply
Door contact.
Exit Button
Installation - The installation of the Switch2 controller is made easy by the colour-coded wiring label xed
to the front of the controller. This clearly identies where each part of the system is to be connected. The
diagram shows the general arrangement for wiring a Switch2 controller.