Q1: What kind of battery is used in E1500 LFP? How long it can last?
A: E1500 LFP utilizes high quality UL certified automotive LiFePO4 battery, it can retain 80% of its original capacity at
3500 complete charge cycles.
Q2: What devices can E1500 LFP power?
A: Please note that the AC output port can only charge or power devices that operate at less than 2200W.
DC output port can only charge or power that operate at less than 12V-30A.
Q3: Can the E1500 LFP be used as UPS?
A: E1500 LFP supports UPS function with an automatic switchover time of 8~20ms.
Q4: Can the E1500 LFP be charged while discharging?
A: Yes, It can be charged and discharged at the same time. In the non-UPS state, if uninterrupted use is required, the
average power of charging must be greater than the average power of electricity, otherwise the battery will
eventually run out and shut down.
Q5: How to calculate the E1500 LFP running time?
A: Running Time=Total Capacity(1536Wh) * 0.85(Depth of Discharge)/Loading Power(Watts)
Q6: Can I use the E1500 LFP indoors and charge the E1500 LFP indoors?
A: Yes, the E1500 LFP is safe to use indoors.
Q7: Does E1500 LFP have built-in MPPT charge controller?
A: Yes, there are two independent built-in MPPT charge controllers; “5521”port supports 12~18V(Max 100W) PV
input, and “GX16MF”port supports 32~95V(Max 700W) PV input.
Q8: How to store the E1500 LFP?
A: Please turn off the unit and then store it in a dry, ventilated place at normal room temperature. Do not place this
unit near water sources or a wet/moist environment. For long-term storage, it is recommended to discharge the
battery to 30% every three months and recharge it to 60% to sustain the battery life.