SOLAR CHARGE TIME
MC4 Solar Charging Cable
Note: The above data comes from PECRON’s laboratory. Actual charging time depends on the weather conditions.
200W
19~20 Hours
Recommended
400W
10~11 Hours
Recommended
USING SOLAR PANELS TO CHARGE THE EP3000-48V
GX16MF-5 Charging Port: PV (operating voltage) range 12V~95V, 400W maximum; VOC (open circuit voltage) of solar
panel/array must be less than 95V, otherwise, it will damage the unit! Do not wire more than two 36V solar panels in
series, or more than four 18V solar panels in series. (18V/36V stands for Vmp, the operating voltage, of the solar panel)
GX16MF-5 Charging Port:
PV12~95V-400W Maximum Input
DC ON/OFF
12V-30A PD 100W 18W
DC INPUT
12~95V-400W
PECRON solar panel