Installer Manual 255-LOGIX 740-760 - System sizing
22 / 76 Ref. MKT-IM-001 / C - 08.10.2019
4.4. Salt amount definition
3 salt settings are available on 740 and 760 controls:
Settings Amount of brine used
Equivalent CaCO
3
L - (Low Salt)
45 [g
salt
/L
resin
]
30 [g/L]
S - (Standard Salt)
120 [g
salt
/L
resin
]
60.2 [g/L]
H - (High Salt)
200 [g
salt
/L
resin
]
75.2 [g/L]