Installer Manual 255-LOGIX 740-760 - Operation
50 / 76 Ref. MKT-IM-001 / C - 08.10.2019
Double regeneration
A After an immediate regeneration has begun, press again to plan a second manual
regeneration.
→ A flashing "x2" symbol indicates the second regeneration will start at the programmed
delayed regeneration time.
Immediate double regeneration
A Press and hold to start the second regeneration immediately following the current
regeneration.
→ A solid "x2" symbol will be displayed.
8.3. To advance regeneration cycles
A Simultaneously press and to advance to the next cycle.
→ An hourglass will display while the camshaft is moving.
→ When the camshaft reaches next cycle, "C2” will be displayed.
B Repeat and to advance through each cycle.
8.4. To cancel a regeneration
A Press and hold and for 5 seconds to cancel the regen.
→ Hourglass will flash once cancelled.
→ Camshaft will move to service position – may take 1 to 2 minutes.