C# Cycle Resin bed
flow
direction
System u1
[minutes]
System u2
[minutes]
System u3
[minutes]
System u4
[minutes]
C2 Brine draw ↓ Calculated Calculated Calculated Calculated
Slow rinse 25 45 25 45
C3 Repressurize None 3 3 3 3
C4 Rapid rinse ↓ 3 3 1 3
C5 2nd backwash ↑ 1 1 1 1
C6 2nd rapid rinse ↓ 1 1 1 1
C7 Brine refill None Calculated Calculated Calculated Calculated
6.10 Resetting the controller
All programmed settings with the exception of time of day can be reset. Entering the value“0” will
reset the flash memory to the factory default.
To reset the controller:
1. Press and hold and simultaneously for 3seconds.
ð A small “u” will be displayed in the left digit.
ð The right digit will display the current system setting.
2. Press until the “u0” system is displayed.
ð Wait 5seconds for the setting to be stored into the flash
memory. The display will return to the time of day.
ð The controller has now system1 setting (default
setting).
3. Follow the steps of the system selection procedure to select
the desired system setting.
6.11 History values
The controller features a review level that displays the operation history of the system. To access
history values :
1. Press and hold and simultaneously for 3seconds.
ð To view the “H” levels.
2. Press to navigate through the table.
ð When the desired code is reached, press to display
the value.
ð Some of the values have four digits. Press to display
the first two digits, then press to display the last
twodigits.