5.3. Integration constraints
Location of a water treatment system is important. The following conditions are required:
level platform or floor;
room to access equipment for maintenance and adding brine (salt) to tank;
constant electrical supply to operate the controller;
total minimum pipe run to water heater of 3 m to prevent backup of hot water into system;
always install check valve to protect the softener from hot water return;
local drain for discharge as close as possible;
water line connections with shut off or bypass valves;
must meet any local and state codes for site of installation;
valve is designed for minor plumbing misalignments. Do not support weight of system on the
plumbing;
be sure all soldered pipes are fully cooled before attaching plastic valve to the plumbing.
5.4. Block diagram and configuration example
Block diagram
Main inlet
By-pass
User’s line
Valve
Resin tank
Check valve to prevent water
harm
Pressure gauge
Can be integrated in the
valve
Drain
Brine tank
Brine line
Drain line
Suggested options
Filter cartridge
Pressure regulator
Meter (only 606)