Installer Manual Magnum 742-762 - Programming
48 / 106 Ref. MKT-IM-012 / C - 25.10.2019
6.3. Basic programming
Note
Menus are displayed in a defined and incremental order.
6.3.1. Basic programming mode chart 742-762/298 valve type
Parameter description Range of values
Default
value
Units of
measure
Notes
Program valve type
255, 263, 268,
278 and
Magnum series
None N/A -
Program system size 5 - 100 / F None liters -
Time setting
1:00 - 12:59 AM
0:00 - 23:59 PM
12:00 PM
hour:
minute
-
Day of week N/A None N/A -
Regeneration time
1:00 - 12:59AM
0:00 - 23:59PM
2:00 AM
hour:
minute
-
Days override
(762 controller only)
0.5 - 99 0 day
0 = no days override.
0.5 = regeneration twice a day
at time of regeneration and
12 hours later.
Days between
regeneration
(742 controller only)
0.5 - 99 0 day
0 = no days between
regeneration.
0.5 = regeneration twice a day
at time of regeneration and
12 hours later.
Amount of brine used per
regeneration
50-290 110 g/l -
Estimated system
capacity
N/A None
kg
equivalent
CACO
3
For information purpose only
on the 742 controller.
Hardness
(762 controller only)
30 - 2000 250
mg/l
equivalent
CACO
3
-

Table of Contents