Installer Manual Magnum 742-762 - Programming
52 / 106 Ref. MKT-IM-012 / C - 25.10.2019
6.3.3.8 Amount of brine used per regeneration
Set desired brine amount in g/L.
6.3.3.9 Estimated system capacity
Note
The system capacity is displayed in kilograms equivalent CaCO
3
of hardness removed
before a regeneration is necessary.
Note
The system capacity is calculated by the Logix software, using the resin volume, brine
dosage and hardness settings.
Note
This parameter can be override for 762 controller and is view only for 742 controller.
Set the estimated system capacity on the controller.
6.3.3.10 Hardness (762 controller only)
Set inlet water hardness at installation site.
A Press .
→ Setting flashes.
B Adjust displayed settings with and .
C Press to validate the selection and advance to the next
parameter using or .
A Press .
→ The amount number flashes.
B Adjust displayed capacity with and .
C Press to validate the selection and advance to the next
parameter using or .
A Press .
→ The hardness number flashes.
B Adjust displayed hardness number with and .
C Press to validate the selection.
→ Initial programming is now complete. The controller will
return you to the normal operation mode.