EasyManua.ls Logo

Pentair AUTOTROL MAGNUM 742 - Advanced programming

Pentair AUTOTROL MAGNUM 742
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer Manual Magnum 742-762 - Programming
Ref. MKT-IM-012 / C - 25.10.2019 55 / 106
6.4. Advanced programming
Note
Press and hold + for 5 seconds to access advance programming. A "P" symbol is
displayed on the bottom left of screen.
6.4.1. Basic programming parameters (5 - Cycle softener system)
* Calculated depending on salt setting and resin volume. The capacity may be manually adjusted.
Parameter description Range of values
Default
value
Units of
measure
Notes
P1 Time of day
1:00 - 12:59 AM
0:00 - 23:59 PM
12:00 PM
Hour :
minute
Range depends on value
selected for P10.
P2 Day of week N/A None N/A -
P3
Time of
regeneration
1:00 - 12:59AM
0:00 - 23:59PM
2:00 AM
Hour :
minute
Range depends on value
selected for P10.
P4 Calendar override 0 - 99 3 Days
0 = no calendar override.
0.5 = regeneration twice a day
at time of regeneration and 12
hours later.
Calendar override skipped if at
least one day of regeneration
selected.
P5
Day of week
regeneration
N/A None N/A
Day of week regeneration is
skipped if calendar override is
more than 0 (742 controller
only).
P6 Salt setting 50 - 290 110 g/l
Unit of measure depends on
value selected for P9.
P7 Capacity of unit 0.1 - 90 * kg
Unit of measure depends on
value selected for P9.
P8 Hardness of water 30 - 2000 400 g/l
Unit of measure depends on
value selected for P9 (762
controller only).

Table of Contents