EasyManua.ls Logo

Pentair AUTOTROL MAGNUM 742 - Diagnostic

Pentair AUTOTROL MAGNUM 742
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer Manual Magnum 742-762 - Programming
60 / 106 Ref. MKT-IM-012 / C - 25.10.2019
6.4.6. Diagnostic
To access diagnostic values, press and hold and for 5 seconds to view the "H" levels.
Diagnostic
Code
Description Unit Range 762 742
H0 Initial setting value Litre
Resin
Volume
Yes
Yes
H1 Days since last regeneration N/A 0 - 255
H2 Current flow rate Depends on turbine used
No
H3 Water used today since time of regeneration
m
3
0 - 61310.70
H4 Water used since last regeneration
m
3
0 - 61310.70
H5 Total water used since reset in 100 s
m
3
0 - 9999
H6 Total water used since reset in 1000000 s
m
3
4264 x 10
4
H7 Average usage for Sunday
m
3
0 - 61310.70
H8 Average usage for Monday
m
3
0 - 61310.70
H9 Average usage for Tuesday
m
3
0 - 61310.70
H10 Average usage for Wednesday
m
3
0 - 61310.70
H11 Average usage for Thursday
m
3
0 - 61310.70
H12 Average usage for Friday
m
3
0 - 61310.70
H13 Average usage for Saturday
m
3
0 - 61310.70
H14 Average service cycle Day 0 - 255
H15 Peak flow rate l/min 0 - 1000
H16 Day and time of peak flow rate
Time and day that peak
flow occurred
H17 Months since service Month 0 - 2184
Yes
Hr Number of regenerations since last service N/A 0 - 65536

Table of Contents

Related product manuals