Installer Manual Magnum 742-762 - Programming
60 / 106 Ref. MKT-IM-012 / C - 25.10.2019
6.4.6. Diagnostic
To access diagnostic values, press and hold and for 5 seconds to view the "H" levels.
Diagnostic
Code
Description Unit Range 762 742
H0 Initial setting value Litre
Resin
Volume
Yes
Yes
H1 Days since last regeneration N/A 0 - 255
H2 Current flow rate Depends on turbine used
No
H3 Water used today since time of regeneration
m
3
0 - 61310.70
H4 Water used since last regeneration
m
3
0 - 61310.70
H5 Total water used since reset in 100 s
m
3
0 - 9999
H6 Total water used since reset in 1000000 s
m
3
4264 x 10
4
H7 Average usage for Sunday
m
3
0 - 61310.70
H8 Average usage for Monday
m
3
0 - 61310.70
H9 Average usage for Tuesday
m
3
0 - 61310.70
H10 Average usage for Wednesday
m
3
0 - 61310.70
H11 Average usage for Thursday
m
3
0 - 61310.70
H12 Average usage for Friday
m
3
0 - 61310.70
H13 Average usage for Saturday
m
3
0 - 61310.70
H14 Average service cycle Day 0 - 255
H15 Peak flow rate l/min 0 - 1000
H16 Day and time of peak flow rate
Time and day that peak
flow occurred
H17 Months since service Month 0 - 2184
Yes
Hr Number of regenerations since last service N/A 0 - 65536