Installer Manual Magnum 742-762 - Troubleshooting
Ref. MKT-IM-012 / C - 25.10.2019 85 / 106
10. Troubleshooting
10.1. Logix controller
Err. code Cause Reset and recovery
ERR 1
Controller power has been connected
and the controller is not sure of the
operating status.
Reset controller.
See 6.4.7. Resetting the controller,
page 61.
ERR 2
Controller power does not match 50 or
60 Hz.
Disconnect and reconnect the power.
If problem is not solved, obtain an
appropriate controller or AC
transformer.
ERR 3
Controller lost the position of
camshaft. Camshaft should be rotating
to find Home position.
Wait for 2 minutes: the controller
returns to Home position.
An hourglass icon flashes to indicate
that the motor is running.
Camshaft does not rotate.
Check:
motor connections;
if motor wire harness is connected
to the motor;
if motor wire harness is connected
to the controller;
optical sensor connection and
position;
if motor and camshaft gears are
engaged.
If everything is connected, try
replacing in this order:
wire harness;
motor;
•optical sensor;
controller.
See 9.6. Cleaning and maintenance,
page 74.
Camshaft rotates for more than 5
minutes to find Home position.
Check:
optical sensor connection and
position;
camshaft connection;
camshaft slots cleanness.