BIFFI ICON 2000 / ICON 2000 AD
Addendum B to InstructIon And operAtIng mAnuAl
ATEX: c Ex d IIB T4 Gb / c Ex tb IIIC T135°C Db IP66/68
c Ex d ia IIB T4 Gb / c Ex tb IIIC T135°C Db IP66/68
IECEx: Ex d IIB T4 Gb / Ex tb IIIC T135°C Db IP66/68
Ex d ia IIB T4 Gb / Ex tb IIIC T135°C Db IP66/68
INDEX
1 Safety instructions ................................. 1
1.1 General ..................................................... 1
1.2 Identification of main parts ..................... 1
2 Check for right application .................... 2
2.1 Marking .................................................... 2
3 Applicable general standards
and regulations ....................................... 2
4 Terms and conditions ............................. 2
5 Manufacturer’s liability ......................... 2
6 Storage and pre-installation ................. 3
6.1 Storage procedure ................................... 3
6.2 Checks to be performed before
installation ................................................ 3
7 Installation .............................................. 3
7.1 Working condition .................................... 3
7.1.1 Models and temperature......................... 3
7.1.2 Base unit with extensions [A]
or [B] or [C] ............................................... 3
7.2 Identification of entry ............................... 3
7.2.1 Base actuator ........................................... 3
7.2.2 Base actuator with extension
[A] on the control compartment ............. 3
7.2.3 Base actuator with extensions
[B] or [C] on the terminal board
compartment ........................................... 4
7.3 Wiring ....................................................... 4
7.4 Cable connection ..................................... 4
7.5 Installation in ambient with
explosive dusts ......................................... 4
8 Maintenance ............................................ 5
8.1 Periodic inspections ................................ 5
8.2 Dismantling and reassembling .............. 5
8.3 Repairs ..................................................... 5
WARNING
It is assumed that the installation, setting,
commissioning, maintenance and repair works
are carried out by qualified personnel and
checked by responsible specialists.
1. SAFETY INSTRUCTIONS
1.1 GENERAL
This Addendum B is an integration to
ICON 2000 main IOM VCIOM-01232 to
prescribe the safety instructions applicable to
all the electric actuators Series ICON 2000 /
ICON 2000 AD either as a base unit either when
they are equipped with an optional extension [A]
for additional entry mounted on the control
compartment or when they are equipped
with an optional extension [B] with additional
entries or with an optional extension [C] with
optional electronic card both mounted on the
terminal board compartment, as identified
by the pictures here below, when they are
installed in Hazardous Areas as defined by the
IEC/EN 60079-10-1 IEC/EN 60079-10-2.
Under the same conditions, the optional
extensions [A], [B] or [C], can be mounted on
a base unit ICON 2000 / ICON 2000 AD already
installed on field.
Both the base unit ICON 2000 /
ICON 2000 AD and optional extension are
designed in accordance with the applicable
international rules and specifications but in
any case the following regulation must be
observed:
- The general installation and safety
regulations.
- The proper use of personal protective devices
(glasses, clothing, gloves).
- The proper use of tools, lifting and transport
equipment.
1.2 IDENTIFICATION OF MAIN PARTS
Base unit
Base unit with extension [A]
Base unit with extensions [B] or [C]
www.pentair.com/valves © 2012 Pentair plc. All rights reserved. VCIOM-03020-EN 15/01