1
SYSTEM FEATURES AND SPECIFICATIONS
Bioshield Features
Our low-pressure, high-output mercury vapor germicidal lamps, convert approximately 40% of their electrical input watts
into UV-C output watts within the germicidal action spectrum (meaning 40% of electricity used is converted into useful
germicidal UV light), the highest UV-C output conversion among all UV lamps.
• UL listed for indoor and outdoor use
• Long lasting, low-pressure, high-ouput lamps (12,000 hours to 80%
efciency).
• Protective Quartz Sleeve (maximizes UV lamp output and
safety)
• Remote Power Supply (10-ft. cable to power supply and 6-ft.
cord)
• UV Resistant High Density Plastic UV Vessel
• Non-UV Transmitting Clear Lamp Viewing Ports
System Specications
Model
No.
No. of
Lamps
M a x F l o w R a t e
@ 30 mJ/cm
2
Lamp
Wattage
Amperes
(A)
UV-C
Output
Watts
Dimensions
H x W
(Inches)
Input
Vo l t ag e
522635
1 25 GPM 50 0.98-0.43 16 28” x 5.75”
120-277 VAC
50/60 Hz
522636 1 45 GPM 80 0.98-0.43 26 43” x 5.75”
120-277 VAC
50/60 Hz
522637 1 62 GPM 120 0.98-0.43 36 56” x 5.75”
120-277 VAC
50/60 Hz
522638 1 90 GPM 150 1.82 47 70” x 5.75”
120 VAC
50/60Hz
522945 1 90 GPM 150 0.81 47 70” x 5.75”
240 VAC
50/60Hz
Sizing Chart
Model
No.
Max Flow
R a t e @
30 mJ/cm
2
Turnover Rate in GPM
Determined by Daily Hours of Operation
6 Hours 8 Hours 10 Hours 12 Hours 14 Hours 16 Hours 18 Hours 20 Hours 22 Hours 24 Hours
522635 25 GPM 9,000 12,000 15,000 18,000 21,000 24,000 27,000 30,000 33,000 36,000
522636
45 GPM 16,200 21,600 27,000 32,400 37,800 43,200 48,600 54,000 59,400 64,800
522637 62 GPM 22,320 29,760 37,200 44,640 52,080 59,520 66,960 74,400 81,840 89,280
522638 &
522945
90 GPM 48,000 48,000 60,000 72,000 84,000 96,000 108,000 120,000 132,000 144,000
Estimated Lamp Life* 5.5 4.1 3.3 2.7 2.3 2.1 1.8 1.6 1.5 1.4
Note (*): Lamp life estimates given above are based on a system that is in continuous operation, 365 days a year. Actual
lamp life will vary based on specic operation schedules.
BIOSHIELD
®