Installer manual Fleck 2850 SXT - Programming
Ref. MKT-IM-030 / C - 12.05.2020 55 / 104
6.5.3 Display format mode (DF)
Select the unit of measure.
Options:
• GAL: U.S. gallons and 12-HourAM/PM;
• Ltr: litres and 24-Hour.
1. Press or to select the unit.
2. Press to validate the selection and move to the next parameter.
6.5.4 Regeneration flow (RF)
Select the regeneration flow.
Options:
• dF1b: standard downflow single backwash (standard);
• Othr: other;
• UFtr: upflow filter (for 5000filter);
• UFbd: upflow brine first;
• FLtr: filter, to be used with standard piston only (except5000);
• dF2b: standard downflow double backwash.
1. Press or to select t the regeneration flow.
2. Press to validate the selection and move to the next parameter.
6.5.5 Regeneration control type(CT)
Select the regeneration controller type.
Options:
• Fd: meter delayed;
• FI: meter immediate;
• tc: time clock;
• dAY: day of the week.
1. Press or to select the regeneration control type.
2. Press to validate the selection and move to the next parameter.