Installer manual Fleck 5600 SXT - Programming
Ref. MKT-IM-013 / E - 23.09.2020 57 / 104
Parameter Options Definition Note
RC Fixed reserve
capacity
0 to 50 % Only displayed for volumetric
regenerations and if set in reserve
selection.
DO Days override 0 to 99 Day -
RT Regeneration
time
00:00:00 to
23:59:59
Hour Regeneration time will not appear
unless regeneration day override is
on.
B1 First backwash 0 to 199 Minute Only displayed for dF2b regeneration
flow. In case of dF1b regeneration
flow, the screen shows BW.
BD Brine draw BD consist of time for brine draw and
slow rinse.
B2 Second
backwash
Only shown in dF2b regeneration flow.
RR Rapid rinse -
BF Brine fill 0 to 199 Minute -
BW Backwash -
Rn Cycle number
n=1 to6
Only if "Othr" is chosen under VT. R1,
R2, R3, etc... will be displayed instead.
Dn Day of week,
n=1 to7
ON - OFF - Regeneration setting for each day of
the week. OFF by default.
Not available for 9000 serie valves.
CD Current day 1 to7 Day of the week Not available for 9000 serie valves
FM Flow meter type P0.7 ¾" paddle wheel -
t0.7 ¾" turbine -
P1.0 1" paddle wheel -
t1.0 1" turbine -
P1.5 1½" paddle wheel -
t1.5 1½" turbine -
P2.0 2" paddle wheel -
Gen Generic or
non-Fleck
-
K Meter pulse 0.1 to 999.9 Litre Only displayed for generic flow meter
type.