Installer manual Fleck 5600 SXT - Programming
Ref. MKT-IM-013 / E - 23.09.2020 59 / 104
1. Press or to select the regeneration control type.
2. Press to validate the selection and move to the next parameter.
6.5.6 Number of tanks (NT)
Select the number of tanks.
Options:
NT1: single tank system;
NT2: double tanks system.
Mandatory
Due to the 5600 valve being designed for single tank system only, set valve type to1.
1. Press or until "---1" is displayed.
2. Press to validate the selection and move to the next parameter.
6.5.7 Tank in service (TS)
Info
This parameter appears only if number of tanks(NT) is set to2.
If it appears, the 5600 valve being a single tank system, go back to number of tanks (NT)
and set it to1.
6.5.8 Unit capacity (C)
Set the unit capacity.
Info
The unit capacity parameter is only available if the controller type has been
programmed for volumetric regeneration.
The unit capacity can be set from 0.1 to 9’999 x1’000 °TH.L if DF = Ltr or from 1 to 9’999
x1’000 grains if DF = GAL.
1. Press or to select the unit capacity.
2. Press to validate the selection and to move the next parameter.
6.5.9 Filter capacity (V)
Set the filter capacity.