EasyManua.ls Logo

Pentair FLECK 5600 SXT - BLFC Cleaning

Pentair FLECK 5600 SXT
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer manual Fleck 5600 SXT - Maintenance
Ref. MKT-IM-013 / E - 23.09.2020 85 / 104
9.4.8 BLFC cleaning
1. Using a wrench, remove the BLFC holder(1).
2. Using pliers, remove the cage(4) form the BLCF holder(1).
3. Remove the BLFC washer(3) from the BLFC holder(1).
4. Clean the BLFC washer(3) with a terry cloth.
5. Clean the cage(4).
6. Lubricate the seal (2) with approved lubricant only.
Caution - material
Risk of damage due to wrong lubricant use!
Do not use petroleum-based lubricants such as vaseline, oils, or hydrocarbon-based
lubricants.
Use only approved silicone grease or soapy water!
7. Reverse above procedure steps to rebuild.
Mandatory
The washers (3) have to be installed with their chamfered side upfront the water
stream flow.
Flow indication must be visible after the washer (3) is placed on the holder (1).

Table of Contents

Other manuals for Pentair FLECK 5600 SXT

Related product manuals