3.3. Description and components location
3.4. By-passing
If the system is equipped with a bypass and if a problem occurs, turn the valves to bypass the system as shown in the picture
below.
4 . Programming
Note: The controller must be plugged to be programmed.
After 5 minutes without any button pressed, the unit returns to normal operation without saving.
4.1. Basic programming
Note: Menus are displayed in a defined and incremental order.
Day of Override
Note: Determine the maximum number of days of operation without regeneration.
Regeneration time
Note: Determine the time of regeneration.
A Press and simultaneously for 5 seconds to enter the menus sequence.
B Select the number of days of Override with and .
C Press to validate the selection and advance to the next parameter.
D Adjust the regeneration time with and .
E Press to validate the selection and advance to the next parameter.
Outlet
Down button
Meter
Inlet
Drain
Brine
Up button
Display
Regeneration button
Mixing device
In Bypass
Out OutIn In
Softening
System
Softening
System
Normal
operation