User Guide Fleck 5600-SXT
Ref. MKT-UG-013 / D - 23.09.2020 7 / 36
EN
Feed Water Hardness
Note: Determine the feed water hardness in °tH.
Reserve capacity
Note: Determine the reserve capacity in Litre or in percentage.
Current day of the week
Note: Determine the day of regeneration (1 for Monday, 2 for Tuesday, 3 for Wednesday, 4 for Thursday, 5 for Friday,
6 for Saturday and 7 for Sunday).
4.2. Diagnostic mode
To access the recorded informations, press and simultaneously for 5 seconds. Press to see the next data. Press
to exit the diagnostic mode.
5 . Operation
5.1. Recommendations
Use only regenerate salts designed for water softening EN973;
for optimal system operation, the use of clean salt free from impurities is recommended (for example salt pellets);
do not use ice melt, block, or rock salts;
the sanitizing process (both with liquid and electrochlorination) introduces chlorine elements which may reduce the lifetime
of the ion exchange resins. Refer to the technical guides for resins in common use, providing necessary checks on the
system.
5.2. Manual immediate regeneration
6 . Error codes
The following error codes may be displayed during operation:
7 . Maintenance
Mandatory: Cleaning and maintenance shall take place at regular intervals in order to guarantee the proper
functioning of the complete system, and be documented in the Maintenance record book.
Mandatory: The maintenance and service operation must be done by qualified personnel only. Failure in respecting this
may void the warranty.
8 . Troubleshooting
Please follow this procedure for any technical support:
A Collect the required information for a technical assistance request.
Product identification (see 2.1. Serial label location, page 5 and Original settings, page 2).
B Contact your local dealer who installed this device (see contact details on last page).
Also call him if the water tastes salty, if the water is not softened or if there is no salt consumption.
F Adjust the water hardness with and .
G Press to validate the selection and advance to the next parameter.
H Adjust the reserve capacity with and .
I Press to validate the selection.
J Adjust the day of the week with and .
K Press to validate the selection.
A Press and hold for 5 seconds.
---0 Cam sense error: Unplug the unit and plug it back. If error continue, call technical support.
---1 Cycle sense error: Unplug the unit and plug it back. If error continue, call technical support.
---2 Regen failure: Perform a manual regeneration. If error continue, call technical support.
---3 Memory error: Call technical support.
Fleck_5600-SXT_UG_VV_Multilingual.book Page 7 Jeudi, 24. septembre 2020 1:40 13