Installer Manual Fleck 5800 - SXT - Programming
Ref. MKT-IM-004 / A - 18.04.2017 49 / 92
6.5. Master programming mode
Note
As soon as programming mode is entered, all parameters can be displayed or set to suit the
needs. Depending on the current programming, some functions will not be displayed or will
not be changeable.
Note
If no button is pressed for 5 minutes in the Programming mode (basic or master mode), or
if there is a power failure, the controller returns to Service mode and changes made are not
saved.
Note
Menus are displayed in a defined and incremental order.
Mandatory
In order to save the new settings in the programming mode, it is necessary to go through all
the parameters.
6.5.1. Master programming mode chart
Parameter Options Definition Note
DF Display format
GAL US units
Ltr Metric units
VT Valve type
5800 -
5810 -
5812 -
RF
Regeneration
flow
dF1b
Std DF single
backwash
dF2b
Std DF double
backwash
dFFF DF fill first
UFFF UF fill first
UFbd UF brine first
FLtr Filter To be used with standard piston only.
UFlt UF filter To be used with UF piston only.
O-dF Other DF
O-UF Other UF