Installer Manual Fleck 5800 - SXT - Programming
50 / 92 Ref. MKT-IM-004 / A - 18.04.2017
CT
Regeneration
control type
Fd Meter delayed
FI Meter immediate
tc Time clock
dAY Day of the week
C Unit capacity
0.1 to
9’999’000
°TH*m
3
Only displayed for volumetric
regenerations.
V Filter capacity 1 to 999’900 L Only displayed for filter.
H
Feedwater
hardness
1 to 1990
°TH, ppm or
grains
Only displayed for volumetric
regenerations.
RS
Reserve
selection
SF Safety factor
rc
Fixed reserve
capacity
cr
Variable reserve
capacity
SF Safety factor 0 to 50 %
Only available if set in reserve
selection.
RC
Fixed reserve
capacity
0 to 50 %
Only displayed for volumetric
regenerations and if set in reserve
selection.
CR
Variable reserve
capacity
DO Days override 0 to 99 Day
RT
Regeneration
time
00:00:00 to
23:59:59
Hour
Regeneration time will not appear
unless regeneration day override is on.
B1 First backwash
0 to 199 Minute
Only displayed for dF2b regeneration
flow.
B2
Second
backwash
BD Brine draw
BF Brine fill
BW Backwash
RF Refill
RR Rapid rinse
SP Service position
SR Slow rinse
Parameter Options Definition Note