Installer Manual Fleck 5800 - SXT - Programming
Ref. MKT-IM-004 / A - 18.04.2017 51 / 92
Cn
Cycle number,
n=1 to 20
BD, BW, RF,
RR, SP, SR,
LC
- Only displayed for O-dF and O-UF.
Dn
Day of week,
n=1 to 7
On - OFF -
Regeneration setting for each day of
the week. OFF by default.
CD Current day 1 to 7 Day of the week
FM Flow meter type
P0.7 ¾" paddle wheel
t0.7 ¾" turbine
P1.0 1" paddle wheel
t1.0 1" turbine
P1.5 1½" paddle wheel
t1.5 1½" turbine
P2.0 2" paddle wheel
Gen
Generic or
non-Fleck
K Meter pulse 0.1 to 999.9 Litre
Only displayed for generic flow meter
type.
RE Relay setting
tb Time based
Fb Flow based
ST Start time
0 to the total
of time of all
the cycles
minus 1
Minute Only displayed for tb.
ET End time
start time to
the total of
time of all
the cycles
VO Volume interval
1 to the total
capacity
Litre
Only displayed for Fb.
TO Time ON 1 to 7200 Minute
Parameter Options Definition Note