Installer Manual Fleck 5800 - SXT - Programming
52 / 92 Ref. MKT-IM-004 / A - 18.04.2017
6.5.2. Entering master programming mode
6.5.3. Display format mode (DF)
Select the unit of measure.
Options:
• GAL: U.S. Gallons and 12-Hour AM/PM;
• Ltr; litres and 24-Hour.
6.5.4. Valve type (VT)
Select the unit of measure.
Options: 5800, 5810 & 5812.
6.5.5. Regeneration flow (RF)
Select the regeneration flow.
Options:
• dF1b: Standard downflow single backwash;
•O-UF: Other upflow;
•O-dF: Other downflow;
• UFlt: Upflow filter, to be used with upflow piston only;
• UFFF: Upflow fill first;
• UFbd: Upflow brine first;
• dFFF: Downflow fill first;
• FLtr: Filter, to be used with standard piston only;
• dF2b: Standard downflow double backwash.
A Press and hold or until the programming icon replaces the service
icon and the parameter display reads TD.
B Set the time to 12:01 PM with or .
C Press to validate the selection and return to the service mode, or wait
for 10 seconds.
D Press and hold and until the programming icon replaces the
service icon and the display format screen appears.
E Press or to select the unit.
F Press to validate the selection and move to the next parameter.
G Press or to select the valve type.
H Press to validate the selection and move to the next parameter.