Installer Manual Fleck 5800 - SXT - Programming
Ref. MKT-IM-004 / A - 18.04.2017 53 / 92
6.5.6. Regeneration control type (CT)
Select the controller type.
Options:
• Fd: Meter delayed;
• FI: Meter immediate;
•tc: Time clock;
• dAY: Day of the week.
6.5.7. Unit capacity (C)
Set the unit capacity.
Note
The unit capacity parameter is only available if the controller type has been programmed for
volumetric regeneration.
Note
The unit capacity can be set from 0.1 to 9999 x 1000 °TH*m
3
, g as CaCO
3
equivalent.
6.5.8. Filter capacity (V)
Set the unit capacity.
Note
The unit capacity parameter is only available if the controller type has been programmed for
filter.
Note
The filter capacity can be set from 1 to 999.9 x 1000 L.
I Press or to select the regeneration flow.
J Press to validate the selection and move to the next parameter.
K Press or to select the controller type.
L Press to validate the selection and move to the next parameter.
M Press or to select the unit capacity.
N Press to validate the selection and to move the next parameter.
O Press or to select the unit capacity.
P Press to validate the selection and to move the next parameter.