Installer Manual Fleck 5800 - SXT - Programming
54 / 92 Ref. MKT-IM-004 / A - 18.04.2017
6.5.9. Feedwater hardness (H)
Set the feedwater hardness.
Note
The feedwater hardness parameter is only available if the controller type has been
programmed for volumetric regeneration.
Mandatory
Enter the feedwater hardness in °TH, ppm or grains of hardness for softener system.
Note
The feedwater hardness can be set from 1 to 1990 °TH, ppm, or grains.
6.5.10. Reserve selection (RS)
Select the reserve.
Note
The reserve selection parameter is only available if the controller type has been
programmed for volumetric regeneration.
Options:
• SF: Safety factor, in % of initial capacity;
• rc: Fixed reserve capacity (fixed volume in L);
• cr: Variable reserve capacity.
6.5.10.1 Safety factor (SF)
Set the safety factor.
Note
The safety factor parameter is only available if this option has been set in reserve selection.
Note
The safety factor can be set from 0 to 50% of the initial volumetric capacity.
Q Press or to set the feedwater hardness in accordance with display
format (DF), see chapter 6.5.3.
R Press to validate the selection and to move the next parameter.
S Press or to select the type of reserve.
T Press to validate the selection and move to the next parameter.