Installer Manual Fleck 5800 - SXT - Programming
58 / 92 Ref. MKT-IM-004 / A - 18.04.2017
6.5.16. Flow meter type (FM)
Select the flow meter type.
Options:
• P0.7: ¾" paddle wheel meter;
• t0.7: ¾" turbine meter (Standard setting for 5800 SXT);
• P1.0: 1" paddle wheel meter;
• t1.0: 1" turbine meter;
• P1.5: 1½" paddle wheel meter;
• t1.5: 1½" turbine meter;
• P2.0: 2" paddle wheel meter;
• Gen: Generic or other non-Fleck meter.
6.5.17. Meter pulse (K)
Set the meter pulse for a non-standard flow meter.
Note
The meter pulse parameter is only available if the Gen option has been set in flow meter type
selection.
6.5.18. Time based relay setting (RE)
Select the relay setting.
Note
The relay can bet set upon a time base (tb) or a flow base (Fb). Only one method can be used
at a time.
Note
If set to tb, the controller will enable and disabled the relay output on set times.
AR Press or to select the flow meter type.
AS Press to validate the selection and move to the next parameter.
AT Press or to set the meter constant in pulses per unit of volume.
AU Press to validate the selection and move to the next parameter.
AV Press or to select between tb and OFF.
AW Press to validate the selection and move to the next parameter.