Installer Manual Fleck 5800 - SXT - Programming
60 / 92 Ref. MKT-IM-004 / A - 18.04.2017
6.5.19.1 Relay volume interval (VO)
Set the relay volume interval.
Note
This option is available only if VR is set to Fb.
Note
The relay volume interval can be set from 1 to the total capacity in litres.
6.5.19.2 Relay time ON (TO)
Set the relay time ON.
Note
This option is available only if VR is set to Fb.
Note
The relay time ON can be set from 1 to 7200 minutes.
6.6. Filter programming
To use the valve as a filter, in the master programming mode, set the regeneration mode (RF) to filter
(FLtr). The controller will let set only the steps necessary to the filter mode, which are: regeneration
control type (CT), days override (DO), regeneration time (RT), backwash (BW), rapid rinse (RR), day of
week (Dn) and current day (CD).
BD Press or to set the relay volume interval.
BE Press to validate the selection and move to the next parameter.
BF Press or to set the relay time ON.
BG Press to validate the selection and move to the next parameter.