Installer Manual Fleck 5800 - XTR - Programming
Ref. MKT-IM-006 / B - 16.01.2018 63 / 122
Valve
Media volume
0.25 to 999 ft
3
1 to 9999 liters
Only required on softener metered
regeneration types.
Salt dosage
3 to 18 lbs/ft
3
50 to 290 g/liter
BLFC size
0.125 gpm
0.250 gpm
0.500 gpm
1.000 gpm
Capacity
1 to 999 999
grams
1 to 9 999 999
grains/degrees
* Liter
Only required on softener metered systems to
calculate treated water capacity and reserve.
Represents total system capacity between
regenerations.
Hardness
1 - 199 grains/gallon
1 - 1999 mg/liter
x - x degrees
Only required on softener metered systems to
calculate treated water capacity and reserve.
Represents hardness of untreated water.
Sensor
sensitivity
Not active Not active
Day override
Time driven
OFF - 1 - 99 days
4, 8, 12, 16 and 20
hours
Mandatory for timeclock systems.
Available to be programmed for all
regeneration types.
4 to 20 hours setting available only for the
timeclock systems
Regeneration
time
12/24 hours clock
Required for time clock and delayed
regeneration types. Set for immediate
regeneration types only when a day override is
also set.
Not available for timeclock system if day
override is set from 4 to 20 hours.
Reserve
Fixed %
Fixed volume
Weekly reserve
Variable reserve
Only available when softener meter delayed
regeneration type is selected.
Selecting fixed % or fixed volume will display
additional configuration options.
Weekly reserve is calculated based on
average day of week's water usage.
Variable reserve is calculated based on
previous day's water usage.
Screen name Parameters Values Notes