Installer Manual Fleck 5800 - XTR - Programming
Ref. MKT-IM-006 / B - 16.01.2018 81 / 122
treatment: Turns the relay ON when the valve is on water treatment.
rapid rinse: Turns the relay ON when the valve is on rapid rinse cycle.
backwash: Turns the relay ON when the valve is on backwash cycle.
Press and to switch screens.
draw: Turns the relay ON when the valve is on draw cycle.
tank refill: Turns the relay ON when the valve is on tank refill cycle.
pause: Can be set with customs and variable refill/brining regeneration flows. Turns the relay ON
when the valve is on pause.
Press to save and to pass to the second relay settings screen if present, or press to return to
the master settings screen without saving.
If already in second relay, or if second relay has not been activated, press to save and to return to
the master settings screen or press to return to the master settings screen without saving.
Aux. #: Cycle Based
tank refill
pause
off
off
on
draw

Table of Contents