Installer Manual Fleck 5800 - XTR - Programming
Ref. MKT-IM-006 / B - 16.01.2018 87 / 122
Note
If a regeneration is scheduled to occur while in the Diagnostic screen, the scheduled
regeneration will start as soon as exit the diagnostic.
Note
Only Peak Flow and Totalizer can be changed, they can be reset to zero by entering the
parameter and then pressing .
Note
Totalizer has a maximum value of 99 999 999. If this number is reached, the totalizer must
be reset to zero to continue tracking this value.
Parameter Description
Flow rate Displays the current flow rate.
Peak flow
Displays maximum flow rate of water since last reset. By entering the
parameter, date and time of occurrence will be displayed.
Totalizer Displays total volume of water used since last reset.
Last Regen Displays time occurred after last regeneration.
Reserve
Displays the reserve volume based on the reserve type selected under master
settings.
Note
This parameter is only available for softener meter delayed regeneration type.
Software Version Displays the software version installed on the controller.
No. of Regens
Displays how many manually and system initiated regenerations the system
has gone through since last reset.
Regen. Interval
Displays the average length of time between regenerations based on the past
four regenerations.
Daily Usage
Displays average water usage for each day of the week based on the usage on
that day for the past six weeks. Enter the parameter to display average water
daily usage. Select each day to display daily consumption for each day of the
past six weeks together with dates. Use the arrows and to come back to
diagnostics screen.
Usage Since
Regen.
Displays water usage since last regeneration.
Last Settings
Change
Displays the time occurred after the last update to master settings.
Seal Life Not available.