Installer manual Fleck 9100 SXT - Description
Ref. MKT-IM-004 / E - 06.10.2020 15 / 108
Protection rating. IP22
Power supply 100 to 240VAC, 50/60Hz, 0.5A, ClassII
Transient overvoltages within the limits of categoryII
Pollution Degree 3
Temporary overvoltages must be limited in duration and in frequency.
Environmental conditions
Indoor use only;
temperature from 5°C to 40°C;
maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50%
relative humidity at 40°C;
mains supply voltage fluctuations up to ±10% of the nominal voltage.
3.2 Performance flow rate characteristics
The graph shows the pressure drop created by the valve itself at different flow rates. It allows
predetermining the maximum flow rate going through the valve depending on the system settings
(inlet pressure etc). It also allows to determine the valve pressure drop at a given flow rate, and
therefore to evaluate the system pressure drop vs flow rate.