Installer manual Fleck 9100 SXT - Installation
38 / 108 Ref. MKT-IM-004 / E - 06.10.2020
5.7 Regeneration flows
Metered
The controller monitors the volume of water used. Once it calculates that there is not enough
capacity for the next operation day, a regeneration cycle will be initiated immediately or at a pre-
set time:
immediate control: the controller measures water usage and regenerates the system as
soon as the system capacity is reached;
delayed control: the controller measures water usage and if the capacity is not reached until
the number of days override, it regenerates the system, at the specified regeneration time.