Installer manual Fleck 9100 SXT - Programming
48 / 108 Ref. MKT-IM-004 / E - 06.10.2020
6.5.1 Master programming mode chart
Parameter Options Definition Note
DF Display format GAL US units -
Ltr Metric units -
RF Regeneration
flow
dF1b Std DF single
backwash
Standard for 9000 Twin valve
dF2b Std DF double
backwash
-
FLtr Filter To be used with standard piston only.
UFbd UF brine first -
UFlt UF filter To be used with UF piston only.
Othr Other -
CT Regeneration
control type
Fd Metered delayed -
FI Metered
immediate
Standard for 9000 Twin valve
tc Time clock -
dAY Day of the week -
NT Number of
tanks
1 Single tank
system
-
2 Double tanks
system
-
TS Tank in service U1 Tank1 in service Only displayed for double tanks
system.
U2 Tank2 in service
C Unit capacity 0.1 to 9’999 (°TH/°dH).L
x1’000
Only displayed for volumetric
regenerations with DF set in Ltr.
1 to 9’999 x1’000 grains Only displayed for volumetric
regenerations with DF set in GAL.
V Filter capacity 0.1 to 9’999 x1’000 L Only displayed for filter with DF set in
Ltr.
1 to 9’999
1 to 9’999
GAL
x1’000 GAL
Only displayed for filter with DF set in
GAL.
H Feedwater
hardness
1 to 1’990 °TH/°dH Only displayed for volumetric
regenerations with DF set in Ltr.
1 to 199 grains per gallon Only displayed for volumetric
regenerations with DF set in GAL.
RS Reserve
selection
SF Safety factor -
rc Fixed reserve
capacity
-
SF Safety factor 0 to 50 % Only available if set in reserve
selection.