Installer manual Fleck 9100 SXT - Programming
50 / 108 Ref. MKT-IM-004 / E - 06.10.2020
6.5.2 Entering master programming mode
1. Press and hold or until the programming icon replaces the
service icon and the parameter display reads TD.
2. Set the time to 12:01PM with or .
3. Press to validate the selection and return to the service mode, or wait
for 10seconds.
4. Press and hold and for 5seconds until the programming icon
replaces the service icon and the display format screen appears.
6.5.3 Display format mode (DF)
Select the unit of measure.
Options:
• GAL: U.S. gallons and 12-HourAM/PM;
• Ltr: litres and 24-Hour.
1. Press or to select the unit.
2. Press to validate the selection and move to the next parameter.
6.5.4 Regeneration flow (RF)
Select the regeneration flow.
Options:
• dF1b: standard downflow single backwash (standard);
• Othr: other;
• UFtr: upflow filter (for 5000filter);
• UFbd: upflow brine first;
• FLtr: filter, to be used with standard piston only (except5000);
• dF2b: standard downflow double backwash.
1. Press or to select t the regeneration flow.
2. Press to validate the selection and move to the next parameter.
6.5.5 Regeneration control type(CT)
Select the regeneration controller type.
Options:
• Fd: meter delayed;
• FI: meter immediate;
• tc: time clock;
• dAY: day of the week.