6.6 Diagnostic
Info
Depending on current settings, some displays cannot be viewed.
If none of the buttons are pushed for 1minute in the diagnostic mode the controller
returns to Service mode.
6.6.1 Commands
1. Press and hold and for fiveseconds to enter the diagnostic mode.
2. Press or to navigate in the diagnostic mode.
3. Press to exit the Diagnostic mode at any time.
6.6.2 Current flow rate (FR)
Info
The display is updated every second.
1. Current flow rate display (L/min or gpm depending on display format
programmed):
6.6.3 Peak flow rate (PF)
Info
The controller registers the highest flow rate (L/min) since the last regeneration.
1. Peak flow rate display:
6.6.4 Hours since last regeneration (HR)
Info
Shows the number of hours since the last regeneration, indicating the length of the
current service cycle.
1. Hours since last regeneration display: