ELECTRONIC SXT
20
1 - VALVE OPERATION
E
N
G
L
I
S
H
Start a manual regeneration
There are 2 options to initiate a manual regeneration:
A) Press and release the button .
The icon will start flashing, to cancel the regeneration request press button, the icon will
stop flashing.
The regeneration will start at the set hour.
B) Press and maintain for 5 seconds the button, the regeneration will start immediately.
Advance to the next regeneration cycle
To advance to the next regeneration cycle, press the button. This will have no effect if the
valve is already advancing to the next cycle.
PROGRAMMING
Caution: The programming has to be done only by the installer for the setting of the valve
parameters. The modification of one of these parameters could prevent the good functioning of
the device.
To enter the programming mode, the valve has to be in service. While in program mode, the valve
will continue to operate normally monitoring all information. The programming is stored in
permanent memory with or without line or battery backup power.
To enter the programming mode, press simultaneously and for 5 seconds.
Press on the button in order to jump to the next stage. Use the and buttons in order to
modify the displayed values.