ELECTRONIC SXT
22
2 - PROGRAMMING
E
N
G
L
I
S
H
1. Press once the button
to go from one display
mode to another.
2. Set parameters values by
using the and
buttons.
3. Depending on the
programmation, some
displays will not appear
and some will not be
variable.
Set the clock on 12:01, and exit time of day programmation
mode by pressing . Then press simultaneously on the
and buttons for 5 seconds.
1. Display unit (DF)
- Gallon [GAL]
- Liter [Ltr]
2. Valve type (VT)
- Down flow, 1 backwash (standard) [dF1b]
- Down flow, 2 backwashes [dF2b]
- Filter, except 5000 [Fltr]
- Up flow, brine draw first [UFbd]
- 8500, not sold in Europe [8500]
- 5000 Filter [Othr]
3. Regeneration type (CT)
- Time clock [tc]
- Weekly time clock [ d AY ]
- Metered delayed [Fd]
- Metered immediate [FI]
4. Valve type (NT)
Valves 9000-9100-9500
Tank in service
i.e.: tank 1 in service
5. System capacity
Only viewed in metered version
- Metrical format m
3
x°tH, i.e.: 200 x1000lx°tH
meaning 200 m
3
x°tH
6. Inlet water hardness (H)
Only viewed in metered version
- Metrical format, French degrees
7. Reserve type (RS)
7.1 Reserve with a fixed volume (RC)
i.e.: 1200 liters
7.2 Safety factor in % (SF)
i.e. : 15% capacity of reserve
8. Regeneration day override (DO)
i.e. : regeneration every 7 days
9. Regeneration time (RT)
i.e.: Regeneration at 2:00 AM