Installer Manual Foleo - Installation
36 / 112 Ref. MKT-IM-038 / C - 15.11.2019
NOTE
Plumbing codes do not allow a direct connection into any sanitary or storm drain, sewer line
or trap. Waste connections or the drain outlet shall be designed and constructed to provide
connection to the sanitary waste system through an air-gap of at least 5 cm This is usually
required so sewer backup will not be back-siphoned into the softener.
CAUTION
When running the drain line to a floor drain, the area around the drain may become wet
during the regeneration process. Keep floor drain area clean at all times to prevent any
damage.
4.5.8. Brine line connection
NOTE
The brine line is internal and is already connected.
Drain
Air gap