EasyManua.ls Logo

Pentair FOLEO 5800 XTR - Page 74

Pentair FOLEO 5800 XTR
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer Manual Foleo - Maintenance
74 / 112 Ref. MKT-IM-038 / C - 15.11.2019
* Wear parts - durability is strongly affected by raw water quality and regeneration frequency
** Electronic parts - durability strongly affected by power source quality and stability.
*** Elastomer - durability is strongly affected by raw water concentration in chlorine and its derivative.
**** **** Seals & Spacer cartridge is equipped with O-rings that ensure watertightness by compression, therefore by
unmounting/remounting the same cartridge may cause it not to be watertight anymore, each time the seals & and spacer
cartridge is extracted from the valve body it must be preplaced by a new one. Note that extraction the piston may also extract
the Seals and spacer cartridge at the same time for this reason it not advised to unmount the piston, clean and lubricate it
with approved grease as with former residential fleck valves for the regular maintenance, but only to replace it at least every
3 years.
Residual
hardness
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Electronic/
settings**
Check Check Check Check
Check/ replace
if necessary
Transformer** Check Check Check Check
Check/ replace
if necessary
Chlorine
generator
Check/ clean/
replace if
necessary
Check/ clean/
replace if
necessary
Check/ clean/
replace if
necessary
Check/ clean/
replace if
necessary
Check/ clean/
replace if
necessary
Meter*
Check and
Clean
Check and
Clean
Check and
Clean
Check and
Clean
Replace
Meter cable Check Check Check Check
Check/ replace
if necessary
Valve
watertightness
Check Check Check Check Check
Valve to piping
watertightness
Check Check Check Check Check
Brine tank &
brine well
Clean Clean Clean Clean Clean
Safety brine
valve
Check and
clean
Check and
clean
Check and
clean
Check and
clean
Check/clean/
replace if
necessary
Air check
Check and
clean
Check and
clean
Check and
clean
Check and
clean
Check/clean/
replace if
necessary
Brine tube Clean Clean Clean Clean
Clean/ replace
if necessary
Brine line Clean Clean Clean Clean
Clean/ replace
if necessary
Cabinet body
and cover
(external)
Clean Clean Clean Clean Clean
Items 1 year 2 year 3 year 4 year 5 year

Table of Contents