Installer Manual Foleo - Maintenance
84 / 112 Ref. MKT-IM-038 / C - 15.11.2019
8.5.7. Other wear and tear parts
8.5.7.1 DLFC cleaning
No. Operation
A
Remove the softener cover, see 8.5.1. First steps, page 76 and 8.5.2. Softener cover
removal, page 77.
B Remove the DLFC locking clip (1) and the DLFC housing (4).
C
Insert one of the pin of the DLFC locking clip (1) in the DLFC washer (2) and extract it from
the DLFC housing(4).
D Clean DLFC (2) using a soft brush or compressed air.
E
Lubricate the seal (3) with approved P-80
®
Emulsion lubricant only.
CAUTION
Using another type of lubricant, such as petroleum-based lubricants (Vaseline, oils, or
hydrocarbon-based lubricants) or silicone grease, may damage the valve.
F Reverse above procedure steps to rebuild.