7
Service Instructions
Fig. 13
Fig. 14
Fig. 15
WEAR PLATE:
Inspect wear plate for excessive wear, surface grooves or impeller contact. Replace
if needed. (Figure 13)
1. Remove two 3/8” stainless steel screws from wear ring. (Figure 14)
Note: Older models have acorn nuts and plastic washers on the front of the
pump. If equipped, remove these first. (Figure 15)
2. Install new wear ring, making sure pump surface and ring are clean and the ring
sits flat against the pump.
3. Reinstall stainless steel screws.
4. Reinstall plastic washers, and acorn nuts on older models.