L-1546 (Rev E) -12-
Installers must provide hydraulic components that are capable of withstanding maximum source pressure.
Theworkingpressuremustbecontrolledbyapressurereliefvalvethatisadjustedtooperateatamaximum
pressure of the hydraulic motor.
For pumps with gas engines, the exhaust must be directed away from operators and anyone standing nearby to
ensure that exhaust fumes do not enter their breathing zone.
If a rigid plumbing system is to be used on a Hypro centrifugal pump, the system must be properly aligned with
the inlet and outlet ports.
Installers must provide hydraulic components that are capable of withstanding maximum source pressure.
Theworkingpressureinthehydraulicssystemmustbecontrolledbyapressurereliefvalvethatisadjustedto
operateat10%ofthemaximumsystempressure.
Wheninstalling,adjustingorremovingaHyprocentrifugalpump,ensurethattherearenoobjectswhichcanfall
ontheinstallerandmakecertainthatallmachinerytowhichthepumpistobeattachedisturnedoff.
Pumps must be installed in a location where they are accessible for any necessary maintenance.
When a main electrical supply is needed to power electric-drive motors, installers are responsible for ensuring that a
supply disconnect device, capable of isolating the machine from its electricity supply, be provided.
Whenhydraulicpowerisused,thesystemshouldcontainaquickdisconnectcouplingthatcanbedisconnected
to isolate the pump.
Standard Mounting
Inordertopreventinjuryordamagetoproperty,allHypropumpsshouldbeproperlymountedtoasolidbasewhere
thereisnodangerofthepumpfallingorbreakingloose.AllHypropumpscomewithmountingholeswhichallow
bolts to be put into the pump so it can be secured to a sturdy base. When mounting your Hypro centrifugal pump, be
sure to use bolts and nuts which are compatible with any chemicals that may come into contact with them as well as
choosing the correct grade of bolt based on the pump weight and any expected loads. Pumps should be mounted
as close to the liquid source as possible. Non self-priming pumps must be mounted below the liquid level to function
properly.
Pump Plumbing
To achieve maximum pump performance the outlet port on the pump should be pointing staight up, and pump
inlet and outlet lnes should be at least the same size as their respective port. Pump plumbing must be capable of
withstanding the maximum suction, and pressure, generated by the pump and should have as few restrictions as
possible.
For best priming results, the upper most vent plug can be removed and a vent line can be installed. This line prevents
airlockandallowsthepumptoprimeitselfbybleedingofftrappedair.
Ref.
No. Description
1 TankLid
2 Vent Line
3 Jet Agitator
4 Shut-offBallValves
5 Centrifugal Pump
6 Spray Control Console
7 Centrifugal Pump Control
8 ManifoldBoomValve
9 Flowmeter
10 JetTurretNozzleBody