- 4-
Hypro roller pumps are designed for creating and boosting pressure in fluid circuits. The economical rotary-action roller
principle requires no check valves, while providing positive displacement characteristics with less friction and lower
starting torque than other pumps. The pump operates by receiving a fluid through the inlet port where it is captured and
transported by the rollers, and then expelled through the outlet port. Construction features include housings and rollers,
which are made in a variety of materials in order to be resistant to a wide range of chemicals. Standard models of roller
pumps rotate counterclockwise, when looking at the shaft end of the pump. Reverse rotation pumps are available.
Description
Intended Use(s)
Introduction
Purpose of Manual
Hypro has provided this manual to provide instructions and requirements that must be met when installing, using and
maintaining the product(s) identified on the cover.
If the product is sold, the seller must pass this manual on to the new owner.
The following special attention notices are used to notify and advise the user of this product of procedures that may be
dangerous to the user or result in damage to the product.
Attention is used to notify of installation, operation, or maintenance information that is important but not safety related.
This symbol is used to denote the presence of an electrical hazard that may result in personal injury, death, or property
damage.
This symbol is used to denote the presence of a hazard that may result in personal injury, death, or property damage.
California Proposition 65 Warning -- This product and related accessories contain chemicals known to the
State of California to cause cancer, birth defects or other reproductive harm.
Hypro roller pumps are intended for creating or booting dynamic pressure and, depending on the type of body, rotor
and rollers used, will work with a variety of fluids. Hypro roller pumps will work in a variety of environments but they
should never be used to pump liquids above 140°F (60°C) or below 34°F (1°C), or when the ambient air temperature
is above 140°F (60°C). Any uses outside of those specified in this manual are considered misuses and are prohibited.
Contact Hypro technical service about any questions regarding specific acceptable uses.