- 9-
Pump Technical Data
Motorized
E
B
J
F
I
C
G
K
D
H
A
Dim. Inch mm
A 5.12 130
B 2.56 65
C 2.54 64
D 5.17 (5.15) 131 (130)
E 3.8 97
F 13.24 (11.91) 336 (302)
G 4.45 113
H 8.79 (7.45) 223 (189)
I 1.5 38
J251
K 2.63 67
Pump Dimensions
Volts PSI GPM AMPS Volts PSI GPM AMPS Volts BAR LPM AMPS Volts BAR LPM AMPS
0 9.4 14.8 0 10.4 17.1 0 35.6 14.8 0 39.4 17.1
5 9.0 16.4 5 10.3 17.5 0.3 34.1 16.4 0.3 39.0 17.5
10 8.6 18.0 10 9.9 19.0 0.7 32.6 18.0 0.7 37.5 19.0
15 8.1 20.1 15 9.4 21.5 1.0 30.7 20.1 1.0 35.6 21.5
20 7.5 23.1 20 8.9 23.8 1.4 28.4 23.1 1.4 33.7 23.8
25 6.9 25.3 25 8.4 26.8 1.7 26.1 25.3 1.7 31.8 26.8
30 6.1 28.5* 30 7.8 29.6* 2.1 23.1 28.5* 2.1 29.5 29.6*
35 5.8 30.3* --- --- --- 2.4 22.0 30.3* --- --- ---
Volts PSI GPM AMPS Volts PSI GPM AMPS Volts BAR LPM AMPS Volts BAR LPM AMPS
0 8.6 10.9 0 9.8 11.6 0 32.6 10.9 0 37.2 11.6
10 8.0 13.3 10 9.1 14.5 0.7
30.2
13.3 0.7
34.3
14.5
20 7.2 17.5 20 8.2 19.5 1.4
27.1
17.5 1.4
30.9
19.5
30 6.0 22.0 30 7.3 23.2 2.1
22.6
22.0 2.1
27.6
23.2
35 5.6 24.4 35 6.8 25.6 2.4
21.0
24.4 2.4
25.6
25.6
40 5.3 36.1 40 6.3 27.8 2.8
19.9
36.1 2.8
24.0
27.8
50 4.7 30.7 50 5.6 31.8 3.5
17.6
30.7 3.5
21.3
31.8
60 3.9 35.5 60 4.9 36.2** 4.1
14.8
35.5 4.1
18.7
36.2**
12.0 (Battery)
Engine Off
13.5
(Alternator)
Engine
Running
Model 4001N-E2H & 4001XL-E2H (Imperial)
Model 4001N-E2H & 4001XL-E2H (Metric)
12.0 (Battery)
Engine Off
13.5
(Alternator)
Engine
Running
Model 4001N-EH & 4001XL-EH (Imperial)
Model 4001N-EH & 4001XL-EH (Metric)
12.0 (Battery)
Engine Off
13.5
(Alternator)
Engine
Running
12.0 (Battery)
Engine Off
13.5
(Alternator)
Engine
Running
Dimensions in ( ) are for 4001-EH
series pumps.
*denotes a duty cycle of 66% (40 minutes on, 20 minutes off)
**denotes a duty cycle of 50% (30 minutes on, 30 minutes off)